Welcome to Industrial Automation Network! 🎉 I'm Daan, working in Industrial Automation. This community is for everyone involved in automation whether you're a programmer, maintenance technician, designer, or student. Our vision is to become the go‑to global community where industrial automation professionals learn, share, and solve real‑world challenges together. Our mission is to empower engineers and technicians by providing practical knowledge, honest peer support, and the tools to grow in PLC, SCADA, robotics, and Industry 4.0 What you can expect here: Weekly tips on PLC programming and SCADA Help with troubleshooting and programming challenges Discussions on best practices, standards, and new technologies Exclusive downloads (checklists, sample code, etc.) The Start Introduce yourself in the comments below: who are you, where do you work, and which systems do you use? Check out the start here post to get you started Questions? Feel free to ask!
The floating signal trap (PNP vs. Sinking)
Alright, quick story. Had a call last week. Customer said the sensor was flashing, so it had to be broken. They swapped out two brand new sensors. Still nothing. Turns out, it was the classic wiring mistake. They used a PNP sensor on a sinking PLC input. The light came on, but the PLC never saw a solid 24V reference. It was just a floating signal. This happens way more than it should. Most people just look at the light and assume the sensor is dead, but the actual issue is in the wiring diagram. My rule of thumb? Check your sinking/sourcing first. If you wire a PNP (sourcing) sensor to a sinking input, it will never work. You either need an NPN sensor or a PLC input that can be configured for sourcing. Also, remember to check your input filter time on the PLC. If you have a 20ms filter set (default on some systems), even the fastest sensor won't register. You have to change that in the hardware config before you swap parts. I've lost hours on this. Now I always grab my multimeter and check the voltage reference before I blame the sensor. What's your experience with this? Do you have a standard way to avoid this trap? Or a story about a "broken" sensor that wasn't actually broken?
0
0
Hey everyone!👋 I'm Michael Peters.
I'm the second person to join this community, and honestly, I'm glad to be here early. Building something from the start is always interesting. I'm 40 years old and I've been in industrial automation for 20 years now. Currently I'm an automation manager, so my days are filled with PLCs, SCADA, integration work, and managing both projects and people. I'm married with two kids, ages 6 and 8. Weekends are for the zoo, and when they're older, roller coasters. That's non-negotiable. When I'm not working I run, fix things around the house, and read when there's time. But here's the thing. I'm not here just to introduce myself. I'm here because I want to help. I've spent two decades dealing with real problems, like stubborn PLC bugs, SCADA systems that don't behave, projects that go sideways, and teams that need direction. If you're stuck on something, ask. If I can help, I will. And if I don't know the answer, I'll tell you straight. Then we figure it out together. No problems unsolved. My goal with my own company is standardized processes and healthy margins. Not for vanity, but because I want to show my kids what good work looks like. I want to be the best automation specialist I can be, for them. So that's me. Now I want to hear from you. Introduce yourself below. Tell us who you are, what you work with, and what you're currently struggling with or trying to improve. Let's make this community actually useful.
Hey everyone!
Hi! I'm Daan Ypma, a student active In the world of Industrial Automation, I study Appllied Computer Science and want to create a community where Industrial Automation proffesionals learn, share and solve real world challenges together. I personally work with PLC's, Robotics & Machinery. Send me a message anytime & help us build this community together.
1
0
📌 Start Here
We're glad you're here. This post will help you get the most out of this community. ✅ 1. Introduce Yourself Go to the Introductions post and tell us: - Who you are - Where you work (or what you study) - Which systems you work with (PLC, SCADA, HMI, robots, etc.) This helps us give you better answers and connect with people in your field. 💬 2. Join the Conversation Here's how to get involved: - Ask questions – No question is too basic. We've all been there. - Share your knowledge – Post tips, lessons learned, or useful links. - Help others – Answer a question or give feedback. - Show your wins – Solved a tricky fault? Finished a project? Let's celebrate. Use the relevant tags (PLC, SCADA, Robotics, Safety, etc.) so others can find your post easily. 🏆 3. Level Up & Earn Points You'll earn points and levels by being active: - Posting and commenting - Getting likes on your content - Helping others Higher levels unlock more visibility and show your expertise in the community. 🛠️ 4. Community Guidelines (Short Version) - Be respectful and professional. - No spam or unsolicited promotion. - Keep discussions technical and helpful. - If you share a link, explain why it's useful. Full guidelines are in the Classroom section. ❓ Need Help? If you're not sure where to post something, or you have a question about the community itself, just reply here or send me a direct message. Let's build the best industrial automation community together. Welcome aboard! 🚀
0
0
1-5 of 5
powered by
Industrial Automation Network
skool.com/industrial-machine-designs-6570
For engineers, technicians, and integrators working with PLCs, SCADA, HMI, robotics, and Industry 4.0.
Build your own community
Bring people together around your passion and get paid.
Powered by